TEC Model 1414

  Acoustic Valve-Flow Indication System

 

.    

97x1.gif (581 bytes) 97x1.gif (581 bytes)

97x1.gif (581 bytes)

97x1.gif (581 bytes)

TEC Model 1414
.
145x1.gif (53 bytes)
IEEE 344, 323 qualified

145x1.gif (53 bytes)

Unequivocal indication
of flow

145x1.gif (53 bytes)

Noninvasive method
145x1.gif (53 bytes)
Qualified to IEEE specifications
145x1.gif (53 bytes)
Easy to install

145x1.gif (53 bytes)

Tamper-proof design
145x1.gif (53 bytes)
Up to 16 channels
in one rack
145x1.gif (53 bytes)
Compact configuration
145x1.gif (53 bytes)
Digital outputs for computer
145x1.gif (53 bytes)

Ganged or individual
channel alarms

145x1.gif (53 bytes)
. Acoustic monitoring of safety and relief valves in nuclear power plants provides reliable indication of flow through the valves so that the operator knows when there is a path open for loss of coolant. This method of valve surveillance satisfies the requirements of NRC Regulatory Guide 1.97 (Dec. 1980) and can be easily implemented using the TEC Acoustic Valve Flow Indication System.

For each valve, a high temperature accelerometer is connected to a TEC Model 504 Charge Converter, which is designed to continue operating under accident conditions. The output of the charge converter is routed by shielded twisted-pair cable to a TEC Model 914 Valve Flow Monitor module. The 914 module, which contains a built-in current source for powering the remote charge converter, performs signal processing and displays ten levels of flow indication. It also provides digital outputs corresponding to a lower trip level, an alarm level, and an upper trip level.

The system is available in both standard 19" wide racks and 9.5" wide racks, containing up to sixteen channels and six channels, respectively. Each system contains power module(s) and alarm module(s). All input and output connections are made at terminal lugs on the rear of the rack. Each 914 module has a front panel BNC connector for auxiliary access to the analog signal.

Optional accessories include a Simulator/Monitor instrument and remote visual indicating meters.

TEC's QA/QC program meets the requirements of 10CFR Part 50, Appendix B, and 10CFR Part 21. For environmental and seismic qualification specific to this product, go to the Model 1414's Qualification page.